Протезирование восходящей аорты по классической методике бентал-ла-де Боно ксеноперикардиальным кондуитом: отдаленные результаты
Бокерия Лео Антонович, Anatoliy I. Malashenkov, Фунг З.Х.Ш. et al. · Annals of Surgery (Russia) · 2012
Material and methods. 130 patients were discharged from Bakoulev SCCVS RAMS after xenopericardial conduit implantation for ascending aorta aneurysm between January 1990 and December 1999. Biological conduit with biological prosthesis of the same tissue was implanted in 25 patients (19.2%), mechanical prosthetic device was implanted in 105 patients (80.8%). Results. Duration of follow-up period in patients with biological prostheses was 10.66 ± 4.7 years (3-17 years). 4 patients underwent reoperation. 8 patients died, 2 of them had acute aortic insufficiency due to dysfunction of biological prosthesis, two other patients died after reoperation and in 4 mortality cases were associated with non-cardiac causes. By the 17 th year of follow-up period it was noted that survival after operation in this group was 28.6%, freedom from reoperation was 65%, freedom from thromboembolic complications was 100%, freedom from infective endocarditis (IE) was 71.3%. According to instrumental studies, freedom from biodegeneration of biological prosthesis was 7% by the 15 th year of follow-up and freedom from biodegeneration of conduit wall was 54.82% by the 17 th year. Mean follow-up in patients with mechanical prostheses was 10.1 ± 3.7 years (1-17 years). Reoperation was required in 3 cases. There were 21 deaths (25%) in a long-term period: in 9 cases the causes were not associated with operation and bioconduits. We noted the following predictors of mortality associated with xenoconduits and mechanical prostheses: prosthetic IE occurred in 3 patients, myocardial infarction in 2 patients (in 4 and 11 years), multiple organ failure after reoperation in 1 patient, acute cerebrovascular accident in 6 years in 2 patients, cardiac insufficiency in 3 patients, coronary anastomosis fistula in 1 patient. Survival in patients with mechanical prosthesis in 10 years after operation was 77.8% and in 17 years it reduced to 75.3% (together with reoperation), freedom from calcification and biodegradation was 49.22%, freedom from reoperation was 95.2%, freedom from thromboembolic complications was 96.4% and from IE 93.1%. Conclusion. The experience of using xenopericardial conduit in surgeries for ascending aorta aneurysms showed satisfactory survival and morbidity rates in a long-term period.
Cited by 0 works.