固相萃取-离子色谱-积分脉冲安培法测定人血清中游离氨基酸
周政华, 杨元, 洪君蓉 et al. · 2007
The efficiencies of precipitating proteins in serum by sulfosalicylic acid and by anhydrous methanol were compared and the conditions of solid phase extraction for purification with 732 cation-exchange resin and gradient conditions of Dionex-600 ion chromatograph (IC) were optimized. On adding 0.8mL sulfosalicylic acid, 0.2mL of human serum was centrifuged at 15000r/min for 15min. All supernatant was diluted to 10mL, and 2.50mol/L NaOH was added to adjust pH to 3.0, and then extracted on 732 cation-exchange resin. Finally, the amino acids was eluted by 5mL ammonia (32:68, V/V). After the ammonia being volatilized over in water bath at 80℃, the eluent was detected by the IC. The separation was performed at a column temperature of 30℃ and at a flow rate of 0.22mL/min. Fourteen amino acids such as glutamine in human serum were detected by the IC. The calibration curve of peak area to concentration for amino acids was linear with a correlation coefficient of 0.9900-0.9995. The minimum detection concentrations, the RSDs of peak area and the recoveries of samples for amino acids were 0.02-0.59mg/L, 1.9%-10.4%, 80.6%-114.8%, respectively.
Cited by 0 works.