Сравнительный анализ колонной станции без боковых платформ с чугунными и железобетонными разделительными стенами
Petr Alexeevich Demenkov, Д. Н. Петров, В. Н. Очнев · Известия Тульского государственного университета. Науки о земле · 2010
Two finite element models of column station without side platforms are considered in the article. In the first FEM model a separation wall is made from cast-iron, and in the second it is made from reinforced concrete. The stress strain state of column station structural elements is given. Results of finite element modeling show that cast-iron separating wall can be replaced by the reinforced concrete one.