Архитектура дифференциальных операционных усилителей с повышенной синфазной помехоустойчивостью

С. В. Крюков, Nikolay Nikolayevich Prokopenko, Конев Даниил Николаевич · Известия Южного федерального университета. Технические науки · 2008

Problems of repeater of current, such as difference from 1 of current transmission coefficient makes negative influence on voltage of zero offset, attenuation of input cophased signals, coefficient of noise cancellation, which appear during a development of sensitive operational amplifiers are considered. Use of compensative cannels under big quantity of different modifications of operational amplifiers with small static error caused by influence of repeaters of current, cophased signal and variation of supply voltage and temperature is supposed.

Cited by 0 works.

Authors