Расчетно-теоретическое исследование влияния установки винтовых ленточных вставок на работу утилизационных котлов в составе СЭУ

Колядин Евгений Алексеевич, Виноградов Сергей Владимирович · OIL AND GAS TECHNOLOGIES AND ENVIRONMENTAL SAFETY · 2008

In accordance with verified methods of heat and aerodynamics analysis of destructor hot-water boilers with screw tape insertions and without them, and with the application of received generalized analytic dependences, the authors of the paper carried out design-theoretical research of operating parameters of destructor hot-water boilers in the system of ship electric power installation of different vessels. The results of comparative investigations showed that with the application of screw tape insertions utilization factor and heat capacity of the boiler increase in average by 38 %, and total aerodynamics resistance increases in average by 16 %, and the outlet exhaust gas temperature is reduced by 12 %, which leads to the reduction of heat emission into the atmosphere. The best results were attained applying screw tape insertions in the destructor hotwater boilers КАУ-4,5.