도시철도 승강장 스크린 도어의 풍압 안정성 해석
송문석, 이승일 · 2012
Installation of screen doors at platform ensures safety of passengers by separating platform from tracks. Besides, it reduces drought and air pressure caused by train conserves heating and cooling energy in the station. In order to guarantee safety of platform screen doors, design considering evaluation of wind pressure requires. In this study, Sosa station, semisealed screen door and EMU are analyzed to estimate the wind pressure of platform screen doors model. Also Sosa station is influenced by climatic condition because it exposed to outside. Therefore, analysis on the wind pressure of platform screen doors is performed under the worst weather condition such as typhoon. The results of analysis, Maximum inside pressure 287 ㎩, and consideration of outside pressure as typhoon to the maximum design pressure of 865 ㎩ 2756.25 ㎩ conditions approximately 3.1 times the difference can be seen that ensure stability.