디젤엔진 흡기포트의 내부 정상유동 해석
곽승우, 이근우 · 한국자동차공학회 춘 추계 학술대회 논문집 · 2006
Steady state flow in Euro-3 4 Valve Diesel engine with a tangential intake port was analyzed CFD. The flow coefficient and swirl ratio calculated by steady state flow CFD analysis were compared with measured values from steady port rig test. The flow coefficient and swirl ratio from the steady state flow CFD calculation and the steady port rig test were compared with maximum error under 20% and 23%. Also the calculation possibility of quantitative analysis from the steady state flow CFD analysis was confirmed.
Cited by 0 works.