전면 막냉각에서 냉각판의 열전도도에 따른 열전달 특성
정의엽, 정희윤, 박세진 et al. · 대한기계학회 춘추학술대회 · 2013
In the present study, total cooling effectiveness was obtained by experiment method on a full-coverage film cooling plate. To confirm the conduction effect of film cooling plate, we conducted three experimental cases. These cases used three different conductive materials, which were polycarbonate, Corian, and stainless steel. The test plates had same hole pattern in the three experiment cases. The hole diameter was 5 mm and the angle of film cooling hole was 35 degree. Spacing to hole diameter ratio (p/d) was 3 on the film cooled plate in both the streamwise and spanwise direction. The jet Reynolds number was controlled to 7,000. The detailed temperature distribution on the film cooled surface was measured using the infra-red thermographic technique. Total cooling effectiveness increased with thermal conductivity of film cooling plate. We demonstrated adiabatic film cooling effectiveness for using this research results.
Cited by 0 works.