시차분할 멀티사이클을 적용한 냉장고의 성능향상에 관한 연구

김기열, 장용희, 정해원 et al. · 대한기계학회 춘추학술대회 · 2008

In this study, the performance improvement of a refrigerator with a time divided multi (TDM) cycle is experimentally investigated by optimizing system parameters. Generally, the TDM type refrigerator cycle shows higher humidity and energy efficiency than a serial type refrigerator cycle. The experiments were conducted in a bench scale TDM type refrigerator by varying the capacity of a suction line heat exchanger, a capillary tube size in the freezer side, and refrigerant charge with a refrigerant storage vessel. The bench tester consisted of the same components used in the refrigerator, which simulated the operating characteristics of the actual refrigerator. The optimization of the capillary tube in the freezer side yielded significant improvement of energy efficiency in the freezer only mode. The performance of each modified cycle was represented in detail in this study.