생체모방형 바이오리액터를 위한 배양시스템 개발

김소연, 지민희, 정훈진 et al. · 대한기계학회 춘추학술대회 · 2013

Recent experimental researches support the hypothesis that mechanical stimuli play a role in regulating specialized molecules expression in articular cartilage in vitro and in vivo. Therefore we are studying bioreactor to provide a stimulus of mimicked real knee environment. Our bioreactor system consists of a joint motion stimulation device and culture chamber. We fabricated a stimulation system similar to movement of the CPM device for human joint motion. This system is composed of a linear stage, ball-spline and links. Also we fabricated a culture system for media circulation and mimicked knee environment. However, previous culture system has some problems that media leakage and interference of joint model. In this study, we improved a new-chamber system for non-interference of joint model and medium sealing. Then, this system could be used to investigate the effect of dynamic culture.

Cited by 0 works.

Authors