산소주입 수처리에 의해 발생되는 급수펌프 밀봉장치의 누설 방지

신정국, 유호선, 이재헌 et al. · 대한기계학회 춘추학술대회 · 2010

The method of water treatment for standard coal power plant had changed from all-volatile treatment to oxygen treatment due to a corrosion of boiler tube and operation costs. That was becoming the cause of serious leakage problems with frequency on mechanical seal of boiler feed water pump. The oxygen treatment increase dissolved oxygen and cause a corrosion on the mechanical seal stationary ring composed of antimony as well as leakage problems. In conclusion, eliminating dissolved oxygen with hydrazine injection can prevent leakage problems of mechanical seal.