태양열발전플랜트의 중온 축열장치용 히트파이프의 열성능

박민규, 곽호협, 부준홍 et al. · 한국태양에너지학회 추계학술발표회 논문집 · 2010

An experimental study was conducted to investigate the thermal performance of a heat pipe having two dissimilar condenser sections which were subject to different boundary conditions. The first condenser dissipates heat to the surrounding air through annular fins by natural convection, while the second one is cooled by a liquid by forced convection at different temperatures. The container and the wick were made of stainless steel and the working fluid was Dowtherm-A for medium-temperature applications. The diameter and length of the heat pipe were 25.4 mm and 1 m, respectively. The maximum thermal load was 1 ㎾ and the operating temperature was around 250℃. The liquid fill charge was adjusted so that the first condenser section may work as an evaporator when the original evaporator was inactive in a vertical configuration. The experimental results were analyzed in terms of thermal resistance and effective thermal conductance against input heat flux and operating temperature.