Определение проксодолола в сыворотке крови с использованием обращеннофазной высокоэффективной жидкостной хроматографии

И. В. Логунова, Н С Богомолова, Виктор Владимирович Чистяков · Химико-фармацевтический журнал · 2006

A reversed-phase high-performance liquid chromatographic method is described for the determination of proxodolol in rabbit blood serum. The HPLC measurements were carried out using Phenomenex (LUNA) C18 column (5 mm). The mobile phase was acetonitrile with 1 mM sodium pentylsulphonate at pH 3.0 (25 : 75, v/v) and a flow rate of 1 ml/min and ultraviolet detection at 272 nm. Sample preparation: The procedure is as follows: to 0.5 ml of rabbit serum is mixed with 100 ml of 2.5 N NaOH and 4 ml chloroform in 10-ml of glass centrifuge tube and the mixture is shaken for 2 minutes and centrifuged at 3000 rpm for 10 minutes. Then, the chloroform phase is transferred to another tube and evaporated to dryness in a flow of nitrogen. The residue is dissolved in 10 ml of 1 mM sodium pentylsulphonate (pH 3 ) and 50 microliters was introduced into a chromatographic column. This method is simple, rapid, sensitive, and has a good linearity. The average recoveriy of proxodolol was 80%. The detection limit was 0.015 mg/0.5 ml. The method was linear in the interval from 0.02 to 1.0 mg/0.5 ml with a correlation coefficient of 0.9996. The coefficient of variation was less than 2% within a day ( n = 5). The method was used for determining some pharmacokinetic parameters for proxodolol upon peroral administration in a dose of 40 mg in a rabbits.

Cited by 0 works. doi:10.30906/0023-1134-2006-40-2-44-46

Authors