비단열 모세관의 전도 열저항 실험 및 전산 해석
이대용, Debasish Sarker, 정지환 · 대한기계학회 춘추학술대회 · 2010
This Paper presents experimental and CFD analysis of conductive thermal resistance of capillary tube-suction line heat exchanger(SLHX). Distilled water was circulated through a SLHX and heat transfer occurs due to temperature difference between the capillary tube-side and the suction line-side. The convective thermal resistances of both sides are subtracted experimental results show that the conductive thermal resistance reaches about 1.5% of total thermal resistance without mass flow rate.