시각적 쾌적성과 에너지 성능분석에 의한 오피스 창호의 적정 투과율 선정

김병수, 임오연 · 대한건축학회 논문집 - 계획계 · 2005

Abstract At present, with the development of using glass in building, visual amenity and energy saving were more concerned. However, it is found at glass performance evaluation that there is more consideration on energy saving than occupant visual amenity. Therefore, this aim of study is to select optimum and minimum transmittance by analysis visual amenity and energy performance used in office glass. The process of the study is as follows: 1)selected 6 transmittances as evaluated value from current film maker in office building window and analysis on construction case. 2) set up Mock-up model, then select 17 evaluated values.3)analyzed cooling-heating load, light energy, daylight glare of office building with the different transmittance change. 4) selected proper transmittance of office building through subjective evaluation of Mock-up experiment, energy performance and glare analysis. As a result of subjective evaluation, the comfort transmittance is from 40% to 60% . cooling-heating load is about 50%, and on glare evaluation the proper transmittance is from 20% to 40%.

Cited by 0 works.