루버 핀 열교환기를 가지는 자동차용 히트펌프 시스템의 착상 특성 연구
임홍영, 송준영, 신성홍 et al. · 한국자동차공학회 부문종합 학술대회 · 2013
The present study investigated the heating performance and frosting phenomenon of the heat pump system for vehicle, which is being developed to increase fuel efficiency of EV(Electric Vehicle) with maintaining thermal comfort. The experimental setup of a heat pump system consists of an electric compressor, an exterior louvered fin-flat tube condenser, an interior condenser, and an evaporator, block type thermal expansion valve and reservoir tank, which are used in actual HVAC system for vehicle. In this study, frosting phenomenon patterns of outside condenser having uniform air flow rate was visualized and heat pump performance is examined experimentally. In addition, the frosting phenomenon is compared with different compressor rpm. As results, non-uniform frosting phenomenon and non-frosting area in exterior condenser was occurred. The heating performance based on air side of interior condenser outlet was maximized within 4min. The heating performance was reduced 5.3% after 27min and 42% after 90min because of frosting in exterior condenser.
Cited by 6 works.