습식 사이클론용 직렬 임팩터의 최적설계
강성현, 임승호, 김가영 et al. · 대한기계학회 춘추학술대회 · 2013
In this study, a novel in-line impactor with the flowrate of 1000 lpm and d50(50% cut size) of 19.5㎛ was designed to be conveniently connected to a wet cyclone. The novel in-line impactor has an orifice unlike previously developed in-line impactors. The collection efficiency of our impactor was predicted through numerical analysis using DPM module in ANSYS 14.5 FLUENT solver. CFD simulations were conducted at a fixed Stokes number varying the size of orifice width (d o ) and distance between an orifice and a nozzle (L n,o ). From the results, it was found that the larger L n,o makes d 50 larger. When d o and L n,o equal to 4.2 mm and 32 mm, respectively, our newly designed impactor has the lowest wall loss rate and a very steep collection efficiency curve like conventional impactors.
Cited by 0 works.