소형 나트륨 히트파이프에서 열유속 변화에 따른 특성에 대한 실험
박철민, 부준홍 · 대한기계학회 춘추학술대회 · 2008
Cylindrical stainless-steel/sodium heat pipe for a high-temperature application was manufactured and tested for transient and steady-state operations. The container material was made of stainless-steel 316, and the working fluid was sodium. Stainless-steel 316 mesh screen was inserted as a capillary structure. The working fluid fill charge ratio was approximately 64 ~ 181 % based on the pore space of the wick. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 ㎜. The evaporator part was 150 ㎜ and the condenser 80 ㎜. The performance test of the heat pipe has been conducted in the furnace with up to 800 W. The variation of the average heat transfer coefficient was investigated as a function of heat flux and vapor temperature. Typical range of the total thermal resistance was as low as 0.06 ~ 0.12 ℃/W at 58.0 ~ 132.6 ㎾/㎡ of heat flux and 730 ~ 980 ℃ of operating temperature.