중고층 모듈러 건축물의 이중보 접합방식에 따른 횡력저항 성능 평가
이근우, 조봉호, 이지형 et al. · 대한건축학회 학술발표대회 논문집 · 2014
Unit module is fabricated in a frame structure at a factory as an independent structure. For this reason, Modular building structure has double-beams and columns unlike general steel structure when modular units are stacked on the site for multi-story building. When it comes to high rise modular building, it is required for a double-beam to have enough lateral load resistant capacity against wind and earthquake load. However, there is an unclear part on behavior of double-beam in modular building structure since the researches on this are insufficient. In this study, Horizontal cyclic load tests were performed with full-size double-beam of modular structure in order to evaluate capacity of its lateral load resistance for high rise modular building..