Condensing species behaviour downstream of a combustor was discussed with particle size distribution in this study. The effects of operating conditions in a biomass combustion facility, i.e. concentration of condensing species, temperature gradient, residence time and injection of adsorbents, on particle size distribution were investigated. Pyroligneous liquid which was completely vaporized at the temperature higher than 350℃ was used as a representative of condensing gaseous species. We found that particle size downstream of a combustor increased with increasing heating temperature (i.e. concentration of condensing species) and residence time. However, temperature gradient was not an important factor to control the particle size. The addition of SiO₂ precursor as an adsorbent could effectively prevent the particle formation by adsorbing condensing gaseous species on SiO₂ particles, and increased the particle size up to 300 nm, resulting in increasing particle removal efficiency in a conventional air pollution control device.