염화물 환경에 있는 에폭시도막철근의 부식 평가 연구

박영수, 최경민, 정시영 et al. · 2006

Five bench scale specimens were used to evaluate corrosion performance of damaged epoxy-coated bars in chloride contaminated concrete. The test specimens were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. Test results using livear polarization technique show that the current density of specimen with conventional steel becomes 0.715 ㎂/㎠ indicating that the steel bars are in moderate or high corrosion conditon. However, the corrosion rates of the specimens with damaged epoxy coated bars are much below 0.1㎂/㎠ and the bars appears to be in passive condition. The corrosion protection performance probided by calcium nitrite is better that that of specimens with the other two inhibitors.

Cited by 0 works.