내부 감육 결함을 갖는 곡관의 손상압력 예비시험
김진원, 나연수, 박치용 · 대한기계학회 춘추학술대회 · 2005
Wall thinning defect due to flow-accelerated corrosion (FAC) is one of the degradation mechanisms of carbon steel piping components in nuclear power plant (NPP), and it results in reducing load carrying capacity and fatigue resistance of the piping components. Especially, the wall-thinning defect leads to abrupt rupture of piping components under normal operating pressure. It is important to accurately evaluate the failure pressure of piping components containing an internal wall-thinning defect for ensuring integrity of piping system of NPP. Therefore, this study set up a system for failure test of wall-thinned elbow and performed preliminary failure tests using two real-scale elbows containing simulated internal wall-thinning under internal pressure. Also, the finite element was performed on the failure tests and the results were compared to the measured data. From these results, the performance of testing system and finite element analysis model were verified.
Cited by 0 works.