제트 팬을 이용한 곡선형 장대터널의 환기특성
김지성, 안종환, 강신형 et al. · 대한설비공학회 학술발표대회논문집 · 2002
In this study, the ventilation characteristics is investigated numerically of the longitudinal ventilation method in the curved long road tunnel. Numerical work has been conducted for the jet fan location by utilizing the commercial finite-volume code, FLUENT. Configuration of the tunnel is three-lane, 1600 m long, 120 ㎡ in area, 3000 m curvature radius. The velocity profile. distribution of carbon monoxide and flow rate of air are examined in the tunnel. Through the analysis, it is found that the difference of ventilation flow rate is a little by the jet fan location, but tunnel outlet setup(case3) of jet fans is the most efficient concerned with carbon monoxide concentration.
Cited by 0 works.