수직튜브 표면의 풀비등열전달계수 향상을 위한 제안

강명기 · 대한기계학회 춘추학술대회 · 2006

To enhance pool boiling heat transfer on a vertical tube surface, a kind of a pulsator has been studied. The pulsator is an annulus with closed bottoms around the tube and has the length of 0.2m. For the test, a heated tube of 19.1㎜ diameter and 540㎜ length and water at atmospheric pressure have been used. Annular conditions are made using glass tubes fabricated around the heated tube. The annular gap sizes of the pulsator are 3.65, 6.35, and 17.95㎜. To elucidate effects of the pulsator on pool boiling heat transfer, results of the pulsators are compared with the data of a single unrestricted tube and the fully annulus with closed bottoms. The pulsator remarkably increases heat transfer coefficients on the surface comparing to the unrestricted vertical tube. Moreover, the pulsator could remove the possibility of heat transfer degradation and the CHF occurrence.

Cited by 0 works.