강제 회전하는 회전체 내부 유동에 관한 열역학적 고찰

윤하용, 안종선, 이인배 et al. · 대한설비공학회 학술발표대회논문집 · 1998

Performance estimation model for a centrifugal impeller using real gases has been developed. The performance estimation model is based on jet-wake theory(Johnston & Dean). In this part, the Primary/Secondary/Mixed Zone model and Two Element in Series(TEIS) model(Japikse) which was formulated for ideal gases has been generalized for real gases. To demonstrate the adequacy of the performance prediction, a comparison of refrigeration compressor data with real gas model and ideal gas model has been conducted. Comparison results show good agreement between real gas and experimental results. The real gas model can improve the design accuracy of centrifugal compressors in non-ideal gas applications, such as refrigeration, chemical process, or steams near two-phase regions.

Cited by 0 works.

Authors