무변압기형 계통연계 인버터의 직류분 보상기법
박봉희, 김승민, 최주엽 et al. · 한국태양에너지학회 추계학술발표회 논문집 · 2013
This paper proposes DC offset current compensation method of trans-less fuel cell/PV PCS. DC off set current is generated due to the unbalanced internal resistance of the switching devices in full bridge topology. The other cause of DC off set current is that the sensitivity of the current sensor is lower than the resolution of the DSP. If inverter is controlled by the current including DC offset, its AC output current will generate DC offset. In case of trans-less grid-connected inverter system, DC offset current is fatal to grid, which results in saturating grid side transformer. Several simulation results with different unbalanced conditions show the difficulties of detecting of DC offset current. Op amp circuit detecting DC offset current functions both amplifier and differential. It provides compensated DC offset component PWM circuit. PSIM simulation verifies that the proposed method is simpler and more effective than using low resolution current sensor alone.