임베디드 부식감지센서를 이용한 해상 콘크리트 교각의 부식 및 음극방식전류밀도의 측정에 관한 연구

정진아, 김기준, 이명훈 et al. · 한국마린엔지니어링학회 학술대회 논문집 · 2007

Recently, corrosion problems have been increased in various structures surrounded by marine environment like marine bridges. Especially tidal and splash zones of concrete piles supported bridge deck are more serious. The most common method of preventing corrosion is the cathodic protection such as impressed current cathodic protection(ICCP) or sacrificial anode cathodic protection(SACP). At any rate, it is necessary to measure accurately corrosion data like potential, cathodic protection current density, and resistivity on the concrete pile to diagnose corrosion. Therefore, a series of laboratory tests have been performed to verify the behavior of corrosion and protection for concrete pile in sea water using the corrosion monitoring sensors. It was useful to monitor the condition change with time using the embedded corrosion monitoring sensors, and the condition change was classified by the location of pile(immersed, tidal, splash, and atmospheric zones).

Cited by 0 works.