열전소자를 이용한 소형 제습기 성능시험 평가

권오경, 윤재호, 김종하 · 대한기계학회 춘추학술대회 · 2006

The objectives of this paper are to examine the effect of thermoelectric module supply voltage, ambient temperature, relative humidity on the electronic dehumidifier by experiment and to find the optimal conditions to design highly effective electronic dehumidifier system. The thermoelectric module and the brush less fan used in the experiments are 40W and 3.36W respectively. Extrusion heat sink is used as the cooling and dissipation of thermoelectric module. The results show that the mass flow rate of condensate increases with increasing ambient temperature and relative humidity in the same supply voltage. Thermal resistance of heat sink increases with increasing supply voltage and ambient temperature. It is found that the mass flow rate of condensate for dehumidifier becomes up to maximum 11.8g per hour in the ambient temperature 35℃, relative humidity 90% and supply voltage 9V. Also, the maximum COP is 0.44 in the supply voltage 6V and ambient temperature 35℃.