钴铬、镍铬、含钛镍铬烤瓷合金在人工唾液中耐腐蚀性能的比较
孙平, 陆瑛, 陈松 · 2007
PURPOSE: To evaluate the corrosion resistance of Co-Cr. Ni-Cr and Ni-Cr-Ti alloy in artificial saliva. METHODS: Electrochemical methods were used to measure the self-corrosion potential (Ecorr), self-corrosion current density (Icorr) and polarization resistance (Rp) of three alloys. And the polarization curves of the three alloys were recorded too. One-way ANOVA with SPSS 11.0 software package was used for statistical analysis. RESULTS: The Icorr of Co-Cr alloy was significantly. lower than that of Ni-Cr alloy (P<0.05) and Ni-Cr-Ti alloy (P<0.05). The Icorr of Ni-Cr-Ti alloy was significantly lower than that of Ni-Cr alloy (P<0.05). The Rp of Co-Cr alloy was significantly higher than that of Ni-Cr alloy (P<0.05) and Ni-Cr-Ti alloy (P<0.05). The Rp of Ni-Cr-Ti alloy was significantly higher than that of Ni-Cr alloy (P<0.05). The Ecorr of Co-Cr alloy was significantly higher than that of Ni-Cr alloy (P<0.05) and Ni-Cr-Ti allay (P<0.05). The Ecorr of Ni-Cr-Ti alloy was higher than that of Ni-Cr alloy hut without significant difference (P>0.05). CONCLUSIONS: The corrosion resistance of Co-Cr alloy is better than that of Ni-Cr and Ni-Cr-Ti alloy. The corrosion resistance of Ni-Cr-Ti alloy is worse than that of Ni-Cr alloy.
Cited by 0 works.