계절별 공동주택 환기성능 평가

김기철, 성상철, 노광철 et al. · 대한설비공학회 하계학술발표회 논문집 · 2011

This study analyzed natural ventilation rates and evaluated the ventilation performance of ventilation systems including hybrid varieties that are capable of complementing the weaker points of natural and mechanical ventilation, by performing actual measurement experiments in the summer and winter under field environments. The results of the evaluation of the summer season ventilation performances of individual ventilation systems showed that room2 satisfied the legal ventilation standard of 0.7 times/hour with natural ventilation alone, both the room2 and the living room were able to use natural ventilation the most with the balanced ventilation system. The results of the evaluation of ventilation performance according to hybrid ventilation system showed that in room2, the ventilation rates of hybrid 2, 3 were similar at 1.17 times/hour and 1.13 times/hour, whereas hybrid 1 exhibited approximately 1.4 times more ventilation rates than hybrid 2, 3. The results of the winter season evaluation of ventilation performance according to individual ventilation systems, show that the room2 and the living room all exhibited the most ventilation rates when using the balanced ventilation system, while mechanical ventilation in all cases satisfied the legal ventilation standard of 0.7 times/hour.