Параметры КОС крови пуповины после родов через естественные родовые пути
Луканская Елена Николаевна, Сержан Тамара Александровна, М.В. Артюшевская et al. · Dalʹnevostočnyj medicinskij žurnal · 2013
70 on term newborns with cephalic presentation after vaginal deliveries were studied with arterial and venous blood sampling from the umbilical cord with subsequent measurement of the acid-base and blood gas. 64 newborns had normal perinatal outcome and 6 ones had hypoxic conditions and clinical signs of newborn encephalopathy. The blood gas values (partial pressure of oxygen (pO 2) and carbon dioxide (pCO 2), pH, bicarbonate ion (HCO3-), standard base excess (SBE) and actual base excess (ABE) of umbilical vein and artery blood were determined in infants. The sensitivity of pH 95% = 54 100 %), specificity is 94 % (P 95% = 84-98 %). The sensitivity of buffer base deficit for predicting poor perinatal outcome is 83% (P 95% = 54 100%), specificity is 98 % (P 95% = 92-100 %). The least effective is the definition of partial pressure of oxygen. Both artery and vein cord samples must be obtained. The difference in values of pH, pCO2, buffer base deficit should be evaluated. Erroneous data and obtaining samples from one vessel result in inadequate determination of acidosis level.
Cited by 0 works.