원자력 발전소 시설에 있어서 콘크리트의 건조밀도 평가에 관한 연구
최경철, 김규용, 남정수 et al. · 한국건축시공학회 학술.기술논문발표회 논문집 · 2010
The facilities producing the nuclear energy chosen for resolving the recent global energy problem have been increasingly constructed, and hence more frequent durability tests on radiation shielding concrete are required due to NPP(Nuclear Power Plant) life extension and increase of radioactive waste repositories. Bulk dry density is one of the critical factors ensuring the durability and performance of the radiation shielding concrete because the design of the radiation shielding reinforced concrete structures for NPPs is based on the bulk dry density of the concrete. Bulk density of unconsolidated shielding concrete can be calculated utilizing a test assuring to satisfy the bulk dry density, or existing credible data set. This study evaluated correlation between bulk density and bulk dry density of the concrete used for Korean NPPs (y=0.9534X+0.0714) and developed a correlation expression considering standard deviation of bulk dry density (y=0.9534X-0.0156).
Cited by 0 works.