한국 표준형 증기발생기 습분제거성능

이병은, 김종인, 김무용 · 대한기계학회 춘추학술대회 · 2004

Moisture contained in the steam generated in the steam generator for large nuclear power plants is removed initially in the moisture separator by the centrifugal force acting on them. Then, the rest of moisture, which is composed of relatively small water droplets, is removed in the dryer vane by inertia force and finally dry steam, which is almost superheated steam, is produced in the steam generator and it is sent to steam turbine to produce electricity. The mechanism of moisture removal is quite complex because of complex geometry and complex flow behavior in it. CFD techniques have been used to investigate the flow behavior and calculate the moisture removal efficiency in the present study. Unit cell test has also been conducted to validate CFD results. Comparison of the numerical predictions for the water droplet removal in a steam generator with experimental data shows very good agreement. However, only CFD results have been discussed in this paper.