太陽光の赤外分光観測に基づく大気微量成分の定量: 南極MAP における赤外分光観測
行雄 牧野, 匡貴 塩原, 久史 村松 et al. · Institutional Repositories DataBase (IRDB) · 1985
As part of the Japanese Antarctic Middle Atmosphere Program (Antarctic MAP), columnar amounts of atmospheric minor constituents such as N_2O, CH_4,CFCl_3,CF_2Cl_2 and HNO_3 were determined from measurements of infrared solar spectra for the period 24 March 1983-29 December 1984 at Syowa Station, Antarctica (69°00′S, 39°35′E). A Fourier-transform-infrared spectrometer was used to measure the solar spectra. The highest apodized resolution of the spectrometer is 0.1(cm)^<-1> (full width at half-maximum), but the resolution of 0.8(cm)^<-1> was adopted in routine operation because of an economy of data processing time and of better signal to noise (S/N) ratio. The accuracy of measurements is estimated from S/N ratios of the obtained spectra; typical errors of measured abundances were ±40,±2 and ±6% for CFCl_3 (at 850(cm)^<-1>), N_2O (at 2576(cm)^<-1>) and CH_4 (at 6004(cm)^<-1>), respectively. A MCT detector (cooled at 77 K) is desirable to attain higher resolutions (∿0.1(cm)^<-1>) and larger S/N ratios.
Cited by 0 works. doi:10.15094/00008483