옥상 외단열 방수 건식화 공법의 단열성능 평가

최영준, 장재희, 이경회 · 대한건축학회 춘계학술발표대회 논문집(계획계) · 1998

A construction method proposed in this paper reduces the cost of reconstruction for fixing the flaw and leads out the recycling of used material when the roof of a building is extended and repaired by substitution the conventional finishing of the roof with prefabricated block. But in the method, as the insulation material is exposed to the air, the insulation performance of prefabricated method is expected to be lower than that of conventional method due to increased water absorption of insulation material. An experiment was conducted to evaluate the insulation performance of bothe methods using a mock-up. As a result, the thermal insulation performance of prefabricated method was lower than that of conventional method by 1.5%.