저비속도 다단 원심 회전차 외경가공시 축추력 평형을 위한 평형피스톤 수정방안
유일수, 박무룡, 윤의수 · 2010
In present study, the unbalance in axial thrust and the change of volumetric efficiency when trimming the impeller diameter have been investigated. Present study is for the low specific speed multistage centrifugal pumps with balance piston as balancing mechanism. The effect of impeller trimming on the axial thrust balance has been compared in multistage pumps with horizontal axis and vertical axis. As a result of impeller trimmings, an additional axial thrust acting to pump inlet direction. Axial thrust unbalance by impeller trim has presented severely in vertical axis pumps than horizontal axis pump. The balance piston's diameter is required to be increasing proportion to impeller trim rate for maintaining axial thurst balance. And increase in piston length in parallel with increase in piston diameter was more effective to reduce axial thrust unbalance and volumetric efficiency drop as well.
Cited by 0 works.