가정용 공조기의 제습운전 조건하에서의 쾌적성에 관한 실험적 연구

전병찬, 김봉훈, 김창현 · 대한설비공학회 학술발표대회논문집 · 1997

For low cooling load, thermal comfort related with a room air-conditioner operated in dehumidifying mode was studied. Theoretical analysis using a computer model was first conducted to examine the effect of of the governing parameters(such as air temperature, relative humidity and air velocity, etc.) on the temporal variation of PPD(Predicted percentage of dissatisfied). From the theoretical analysis, Both air temperature and air velocity were found to be the most dominant parameters as to control PPD of a test room. Several experiments were also performed to investigate thermal comfort of a room air-conditioned in dehumidifying mode. From the results, two important conclusions were made as: 1. In the case of dehumidifying mode representing low cooling load, indoor degree of humidity tends to approach that of outdoor's. Finally, moisture potential of the two rooms reach an equalized state as a result of moisture diffusion while the room air-conditioner with constant speed compressor is repeating periodic ON-OFF cycle. 2. Indoor environment should be evaluated in view of PPD instead of relative humidity commonly recognized as an important index particularly in dehumidifying mode since PPD includes all the effects caused by the changes in the influencing parameters.

Cited by 0 works.