세라믹 볼을 이용한 판형열교환기 세정장치의 볼 회수율 측정에 관한 연구
채희만, 권오경, 권정태 et al. · 대한설비공학회 2013년도 하계학술발표대회 · 2013
The purpose of this study is to measure the ball recovery rate of cleaning apparatus for plate heat exchanger. The recovery rate are derived with change in recovery time and flow rate of water. The results show that the recovery rate increases with increase in the recovery time and the flow rate of water. The recovery rate reaches the peak at 0.5 m/s of the flow rate and 25 minutes of recovery time.