모터구동 게이트밸브의 열림행정시 차압 작용에 의한 부하율 연구
김범년, 홍성인 · Journal of the Korean Society of Propulsion Engineers · 2007
The rate of loading in motor operated valve(MOV) can be defined as a variation of correlation between the actuator torque and the thrust upon the variation of operating load. This paper contains the analysis of characteristic and the validity of loading rate in the opening stroke of gate type motor operated valve. Also, this paper describes the evaluation result of loading rate for 40 MOVs opening stroke using newly derived methodology in this study. Author has found a result that loading rate of opening stroke gets a negative value when the differential pressure is higher than 150 psi and this value goes up depending on the amount of the differential pressure.
Cited by 0 works.