배관 감육손상 건전성 평가 적용코드 분석 비교
박치용, 이성호, 김진원 · 대한기계학회 춘추학술대회 · 2005
Wall thinning defect due to flow-accelerated corrosion is one of major aging phenomena in the carbon steel pipe in the nuclear power plant. Therefore, a considerable amount of studies have been conducted to establish the integrity evaluation procedure for wall thinned pipe and flaw acceptance criteria for thinning damage. Several criteria and evaluation procedures were proposed as code and standard based on these efforts. In this paper, the codes and standards related to the evaluations of integrity and local allowable thickness for wall thinned pipe were reviewed and analysed, and its application was investigated. Application procedures of analytical evaluation method and acceptance standards were compared, and the limitations of its application were discussed. Application status also was mentioned. Applicable and acceptable code and standard have to be developed for integrity evaluation of wall thinned pipe, and also development philosophy was proposed.
Cited by 0 works.