가스버너에서 혼합관 길이와 노즐 거리가 연소특성에 미치는 영향

임재범, 김영수, 양대봉 et al. · 대한기계학회 춘추학술대회 · 2009

In this study, the excess air ratio and CO & NOx emission is measured according to the distance from the nozzle to the mixing tube inlet. The results showed that the excess air ratio becomes difference according to the mixing tube diameter. The diameter of the one mixing tube burner is 1.7 times bigger than the diameter of the double mixing tube burner. In case of one mixing tube burner, there is not big difference according to the nozzle distance. But in case of double mixing tube burner, the excess air ratio is some difference according to the nozzle distance. So we can know that mixing tube diameter is important factor through this study. The CO emission and NOx is not big difference according to the distance from the nozzle to the mixing tube inlet. Additionally, the excess air ratio is increased as the mixing tube length is increased.

Cited by 0 works.