딤플에 의한 루우버휜 열교환기의 공기측 압력강하, 열전달 및 배수 성능향상

강희찬, 오현식, 임무기 et al. · 한국자동차공학회 부문종합 학술대회 · 2011

The present study proposed a dimpled louver fin by adding dimpled slots between the end region of louver fin and the brazing line of the flat to reduce flow resistance and enhance drainability. Numerical simulations were conducted for the conjugated heat transfer of 2 kinds of fin geometry by using the commercial CFD code. The drainability was tested for the four enlarged plastic models made by the rapid prototype machine. The dimpled louver fin showed 14% less airflow pressure drop coefficient than the baseline louver fin, the advantage increasing at low air velocity. The dimpled louver fin shows up to 5% higher than the baseline fin in the performance index of the heat transfer capability per unit temperature potential for the same fan power. The dimpled louver fin drained water better and held substantially less than the baseline fin in the deep test.

Cited by 9 works.