플라즈마/광촉매 결합시스템에 의한 톨루엔 제거특성

여석준, 허용숙 · 한국동력기계공학회 학술대회 논문집 · 2007

The main purpose of this study is to analyze the characteristics of toluene removal by plasma, photocatalyst, and plasma/photocatalyst system with the major parameters such as flow rate, inlet toluene concentration and applied voltage, etc., experimentally. In the combined plasma/photocatalyst process, rates of toluene conversion are represented as 99% at flow rate 250, 500 ㎖/min while, below 97% at flow rate 1000 ㎖/min due to the low residence time(reaction time) at the same applied voltage 4173 voltage and toluene inlet concentration 50 ppm. The intermediate products are detected by GC/MS analysis showing the small amounts of benzoic acid, benzyl alcohol and residual ozone concentration 0.04~0.05 ppm generated by plasma process in the present system.

Cited by 3 works.

Authors