정전탐침법에 의한 예혼합난류전파화염의 구저에 관한 연구

城戶 裕之, 김준효, 안수길 · 한국자동차공학회 춘 추계 학술대회 논문집 · 1994

The structure of premixed turbulent flames in a constant-volume vessel was investigated using a microprobe method. The flame potential signal having one to eight peaks was detected in the case of turbulent flames, each of them being regarded as a flamelet existing in the flame zone. Based on this consideration, the flame propagation speed, the thickness of the flame zone, the number of flamelets and the separation distance between adjacent flamelets in the flame zone were measured. The experimental results of this work suggest the existence of behind the flame front when the turbulence was intensified to some extent. The critical(lowest) ratio of the turbulence intensity to the laminar burning velocity being found to be about 0.7 for the formation of reactant islands in this experiment.

Cited by 0 works.