중탄산나트륨이 첨가된 여과집진기를 이용한 염화수소의 제거
이건주 · 2007
The purpose of this study was to investigate the removal efficiencies of HCl in dry reactor and Bag-Filter system. The bicarbonate was used as adsorbent to measure the HCl removal rate. The performance of bicarbonate was evaluated to investigate the removal efficiency. It was analysed that the best operation condition in using bicarbonate in process. The operating parameters was residence time, stoichiometric ratio, temperature and pressure. The Residence time was 1.5 sec, stoichiometric ratio was 1SR, 1.25SR, temperature was 160℃, 180℃, 200℃ and the bag filter pressure was 210㎜Aq, 230㎜Aq, 250㎜Aq. In this study it was found that the stoichiometric ratio and pressure can be effected in removal of HCl however the removal efficiency do not depends on temperature. The best operating condition was on 1SR, 230㎜Aq and 180℃ respectively and in this condition the best removal rate was 99.50%
Cited by 0 works.