Определение антиаритмического средства ниферидила в сыворотке крови с использованием обращеннофазной высокоэффективной жидкостной хроматографии

Светлана Михайловна Филимонова, Н С Богомолова, Виктор Владимирович Чистяков · Химико-фармацевтический журнал · 2011

A reversed-phase high-performance liquid chromatography (RP-HPLC) technique is described that can be used for the determination of niferidil in rat blood serum. The RP-HPLC procedure is carried out on Silasorb SF C8 column (150 × 4 mm, 5 μm) eluted with a methanol-water (45:55) mobile phase (adjusted to pH 2.5 with orthophosphoric acid and then to pH 2.5 with propylamine) at a flow rate of 1 ml/min, with UV detection at 265 nm. The procedure is as follows: mix 1 ml of rat blood serum, 100 μl NaHCO3, and 3 ml chloroform in 10 ml glass centrifuge tube. Shake for 2 min and centrifuge at 3000 rpm for 10 minutes. Transfer chloroform phase into another tube and evaporate to dryness under a flow of nitrogen. Reconstitute the residue in mobile phase (100 μl) and inject 20 μl into the chromatographic column. This method is simple, rapid, sensitive and has good linearity. The average recovery of niferidil is 70 %. The detection limit is 15 ng/ml. The method was linear from 0.02 to 0.5 μg/ml with a correlation coefficient of 0.968. The coefficient of variation was less than 12 % within a day (n = 5). The proposed method was successfully used to determine some pharmacokinetic parameters after the intravenous injection of niferidil in rats.

Cited by 0 works. doi:10.30906/0023-1134-2011-45-12-45-47