와전류에 의한 저주파 자기장 차폐 성능 평가

최학윤 · 2010

In this paper, the shielding effectiveness of aluminum shielded room with using eddy-current is calculated and measured after fabricated. The size and thickness of shielded room are decided as 2.4 × 2.4 × 2.4[㎥] and 12[㎜] after AC shielding characteristics by eddy-current of conductive materials is analyzed. To verify the shielding effectiveness, a rectangular helmholtz coil is fabricated to generate magnetic field of 1.37[μT] and measured magnetic field inside shielding room for 0.01~10[㎐]. According to calculations and measurements, AC Shielding effectiveness by eddy-current in aluminum is very small for 0.01~2[㎐] and 5 times to 11 times for 5~10[㎐].

Cited by 0 works.