불평형 전압 인가시 유도전동기 전류 불평형율 계산
김종겸, 박영진, 이은웅 et al. · 대한전기학회 학술대회 논문집 · 2006
The current unbalance occurs in an induction motor with the supply of unbalanced voltage. Existence of an current unbalance occurs by various problems at the time of driving by in crease of the noise not to mention output decrease of a motor by increase of a loss. We confirmed how current unbalance occurred by a voltage unbalance because a slip came to change by the driving situation of a subordinate as for the induction motor. We confirmed that case ta run to a low slip in a ratio of the same voltage unbalance rate brought a high current unbalance rate.
Cited by 0 works.