요크형 교류 전자기장과 선형배열 홀 센서에 의한 결함 탐상 및 평가

전종우, 이진이 · 대한기계학회 춘추학술대회 · 2009

Linearly integrated Hall sensor array (LIHaS) and combined induced current and magnetic flux leakage (CIC-MFL) for crack inspection is developed by Lee, et at. Distorted alternate currents (DAC) are produce around the crack tips when the current is induced on the specimen in the CIC-MFL system. The alternate MFL resulting from the DAC is detected using LIHaS. The root-mean-square (RMS) value of the MFL obtained by using high pass filters after the use of the Hall sensor is converted to a digital signal by an analog-to-digital converter (ADC), stored in a computer, and processed by interface and operation software. An algorithm for the quantitative nondestructive testing and evaluation of cracks of different shapes and sizes on the aluminum alloy, Al7075, is proposed in this paper.

Cited by 1 works.

Authors