반복 횡하중을 받는 내부 철골 보-기둥 접합부의 이력거동
양철민, 유장열, 김영문 · 대한건축학회 학술발표대회 논문집 - 구조계 · 2006
Demage to several steel moment-resisting frames involving brittle failure of welded beam-to-column connections, such as that which occurred in the 1994 Northridge, has emphasized some drawbacks related to welding. Receltly, bolted connections have become an important alternative in consideration of their good performance inpast earthquakes. In particular, bolted beam-to-column connections are the common forms of moment-resisting frame joints. The high-strength bolted connection has the advantage of eliminating the difficulties of shop or field welding. However, because the behavior of the beam-to-column connection used high-strength bolts is complicated and possessed low strength capacity and its design has not been sufficiently verified, their use has been limited. The objetive of the preset paper is to describe an experimental program carried out at the Univesity of Chonbuk on three type of beam-to-column connectios under cyclic loads. These specimens were double-side beam-to-column assemblies that are representative of interior beam-to-column connections, and they were composed of same beam and column sizes but had the different connection details. The investigation focused on the failure patterns, the hysteretic behavior, and cpapcity.
Cited by 0 works.